Experiment Analysis Settings
Set a Statsig experiment's target duration and the significance level Statsig applies to its results, including Bonferroni correction and the default confidence interval.
Two settings control how long an experiment should run and how strictly Statsig reports its results: the target duration and the significance level. Set them both from the experiment's Setup tab. If wanted you can change the significance level from Experiment Results.
Target duration
A target duration is optional. It helps you wait long enough for the experiment to reach full power. Your organization sets the default and the minimum, and the console shows the default beneath the field. Use the Power Analysis Calculator to determine which target works best for your metrics.
Set the target duration from the Target Duration section of the Setup tab, as a number of Days or a number of Unique Exposures. Days and Unique Exposures are alternatives, not a pair: an experiment carries one target. Setting a new target removes the other. An exposure is a single experimental unit enrolled in the experiment, typically a user or a device for device-level experiments.
Target durations longer than 90 days: By default, Statsig computes Experiment Results for the first 90 days, though the experiment itself can run longer. Before you set a duration beyond 90 days, consider whether results past that period are still relevant, and whether earlier data might already provide the insights you need. This applies to targets set in Days. The console doesn't raise the 90-day warning when you target unique exposures.
After you set the target, you can track progress against the target duration or exposure count in the experiment header. Statsig also notifies you through email and Slack (if integrated) when you reach the target.
A target duration doesn't stop the experiment. Reaching the target notifies you, but the run continues until you end the experiment or until a scheduled stop you set runs.
Advanced Settings
The rest of an experiment's analysis options live in the collapsed Advanced Settings section at the bottom of the Setup tab, split into Analysis Configuration and Experiment Population.
Analysis Configuration
- Analytics Type: Choose Frequentist, SPRT, or Bayesian. Each choice reveals its own settings block. Set it before you start the experiment, because the analytics type locks once the experiment starts.
- Default Confidence Interval: Choose 80%, 90%, 95%, 98%, or 99%. A lower confidence interval gives faster, more directional results with a higher tolerance for false positives. Alpha is one minus this value.
- Apply Sequential Testing: Adjusts confidence intervals to reduce false positives when you read results before the experiment reaches its target duration. This option appears only after you set a target, in either days or unique exposures.
- Multiple Hypothesis Corrections: Expands to five options, described in Significance level adjustments.
- Specify Default Date Filter: Sets the date range results open with. Without it, results use a cumulative filter over all available days.
Experiment Population
- ID Type: The unit Statsig randomizes. Go to Create an Experiment.
- Stratified Sampling: Balances groups on a metric or classification before the experiment starts. Go to Stratified sampling.
- Configure Allocation Duration: Stops enrolling new users after a set number of days. This works only when your SDK uses Persistent Assignment for the experiment, or when the experiment runs on a one-time surface such as signup. Without one of those, users enrolled earlier stop receiving their group's experience.
Significance level adjustments
Your organization sets the defaults for confidence interval and multiple-hypothesis correction, so a new experiment may not start at 95% and uncorrected. Change them per experiment under Advanced Settings, and change the confidence interval later from the Comparison & Stats panel on the Results tab.
Selecting Multiple Hypothesis Corrections reveals the following, and you can't combine a Bonferroni option with a Benjamini-Hochberg one:
- Apply Bonferroni Correction Per Variant: Divides the significance level (α) by the number of test groups. Applies only with more than two variants.
- Apply Bonferroni Correction Per Metric: Divides α across the metrics in the scorecard. Set Primary Metric Weight to the share of α that goes to primary metrics. For the calculation, go to Bonferroni correction.
- Apply Benjamini-Hochberg Procedure Per Variant and Per Metric: Control the false discovery rate instead of the family-wise error rate. For the calculation, go to Benjamini-Hochberg procedure.
- Apply Benjamini-Hochberg Procedure for Primary Metrics Only: Appears when you select Per Metric, and narrows the correction to primary metrics. Clearing Per Metric also clears this option.
Organization admins set the project-wide defaults for these options, along with limits such as the minimum target duration. For the full list, go to Experiment policies.