For AI agents: a documentation index is available at /llms.txt. Append .md to any page URL for markdown, or send Accept: text/markdown.

Retrieve Pulse Results

Retrieve Pulse Results

gethttps://statsigapi.net/console/v1/holdouts/{id}/pulse_results

Authorizations

STATSIG-API-KEYstringrequired

apiKey (header)

Path parameters

idstringrequired

id

Query parameters

cupedstring

Whether to apply CUPED. Allowed values are "true" or "false".

confidencestring

Confidence interval (0-100)

Response

application/json
200· Get Pulse Results Success
messagestringrequired

A simple string explaining the result of the operation.

dataobjectrequired
Show child attributes
dsstringrequired
monitoringMetricsobject[]required
metricIDstringrequired
metricNamestringrequired
directionalitystringrequired

Indicates the desired change direction for the metric. Use "increase" for positive changes and "decrease" for negative changes.

Allowed values:increasedecrease
Example:increase
erroroneOf

Machine-readable reason when pulse statistics are unavailable. Common values include no_data (insufficient data), echidna_unripe (not yet loaded), and setup_incomplete (misconfigured metric source). Additional string values may appear for cohort/bake windows or other load failures.

Example:no_data
Constraints:nullablestringstring
warningsstring[]

Human-readable warnings about metric data quality, load state, or partial pipeline failures.

absoluteChangenumber
confidenceIntervalDeltanumber

Absolute confidence interval delta

confidenceIntervalobject

Confidence interval bounds

Example:{"lower":-1.33,"upper":1.33}
lowernumberrequired
uppernumberrequired
percentChangenumber
sequentialTestingConfidenceIntervalDeltanumber
sequentialTestingConfidenceIntervalobject

Confidence interval bounds

Example:{"lower":-1.33,"upper":1.33}
lowernumberrequired
uppernumberrequired
percentConfidenceIntervalDeltanumber
percentConfidenceIntervalobject

Confidence interval bounds

Example:{"lower":-1.33,"upper":1.33}
lowernumberrequired
uppernumberrequired
percentSequentialTestingConfidenceIntervalDeltanumber
percentSequentialTestingConfidenceIntervalobject

Confidence interval bounds

Example:{"lower":-1.33,"upper":1.33}
lowernumberrequired
uppernumberrequired
testMeannumber
controlMeannumber
testStdnumber
controlStdnumber
testUnitsnumber
controlUnitsnumber
pValuenumber
sequentialTestingPValuenumber
Constraints:nullable
adjustedAlphanumber
reversePowernumber
percentCredibleIntervalobject

Bayesian credible interval for the percent change. Only returned when results are computed with Bayesian analysis.

Example:{"lower":-1.33,"upper":1.33}
lowernumberrequired
uppernumberrequired
expectedLossnumber

Bayesian expected loss. Only returned when results are computed with Bayesian analysis.

chanceToBeatnumber

Bayesian probability that the test beats the control. Only returned when results are computed with Bayesian analysis.

sequentialTestingLikelihoodRationumber

SPRT likelihood ratio of the observed data under the alternative vs the null. This is the same value Pulse uses.

sequentialTestingLogLikelihoodRationumber

Natural log of the SPRT likelihood ratio Pulse uses. Compare this to sprtLogLowerLimit and sprtLogUpperLimit.

sprtLowerLimitnumber

Lower SPRT decision boundary on the likelihood-ratio scale. Crossing below this accepts the null.

sprtUpperLimitnumber

Upper SPRT decision boundary on the likelihood-ratio scale. Crossing above this accepts the alternative.

sprtLogLowerLimitnumber

Lower SPRT decision boundary on the log-likelihood-ratio scale. Crossing below this accepts the null.

sprtLogUpperLimitnumber

Upper SPRT decision boundary on the log-likelihood-ratio scale. Crossing above this accepts the alternative.

sprtDecisionstring

SPRT decision from the log likelihood ratio. alternative accepts H1, null accepts H0, and continue means the ratio is still between the boundaries.

Allowed values:alternativenullcontinue
isSprtSignificantboolean

True when the SPRT decision is alternative, meaning the result is statistically significant.

sprtStatsignessstring

Direction of the SPRT decision relative to the metric's desired direction. neutral when the test has not accepted the alternative.

Allowed values:positivenegativeneutral
absoluteToplineImpactnumber
absoluteToplineImpactDeltanumber
relativeToplineImpactnumber
relativeToplineImpactDeltanumber
projectedAbsoluteToplineImpactnumber
projectedAbsoluteToplineImpactDeltanumber
projectedRelativeToplineImpactnumber
projectedRelativeToplineImpactDeltanumber

Was this helpful?